Why lint is the thing to watch
A dryer pushes hot, damp air out of the drum and down a duct to the outside. A federal housing inspection standard describes that exhaust as removing heated air, moisture and lint.
The Consumer Product Safety Commission (CPSC) explains what goes wrong. Fires can occur when lint builds up in the dryer or in the exhaust duct. Lint can block the flow of air and cause excessive heat build-up, and in some dryers that ends in a fire.
So lint collects in three places: on the lint screen, inside the dryer, and in the vent, which some people call the dryer duct. This guide is about the screen and the vent.
What the fire statistics say
Two national reports measure dryer fires. Each has its own method and its own years, so they are shown side by side here and never added together.
| Report | Fires a year | Share from failure to clean |
|---|---|---|
| U.S. Fire Administration, published August 2012, data for 2008 to 2010 | An estimated 2,900 clothes dryer fires in residential buildings, with 5 deaths, 100 injuries and $35 million in property loss | 34 percent, the leading factor contributing to ignition |
| National Fire Protection Association (NFPA), published June 2020, data for 2014 to 2018 | An estimated average of 13,820 home structure fires involving dryers, with seven civilian deaths, 344 civilian injuries and $233 million in direct property damage | 32 percent, which NFPA says appears to be mainly lint build-up |
The totals are far apart because the counting differs. The Fire Administration counts fires in residential buildings with its own national estimates method. NFPA counts home structure fires, and its figure includes 1,280 minor fires a year that stayed confined. Neither report reconciles the two. Both are several years old, and they are the latest national figures we found.
Three more details from these reports are worth knowing:
- What burns first. In the Fire Administration’s data, dust, fiber and lint were the first thing to ignite in 28 percent of the fires, and clothing in 27 percent.
- Gas and electric alike. In NFPA’s data, 78 percent of the dryers involved were electric and 22 percent were gas. NFPA says that split is generally in line with how the two types are used.
- Lint is not the whole story. In NFPA’s data, mechanical failures or malfunctions caused 27 percent of home dryer fires and electrical failures or malfunctions 16 percent. A clean vent lowers the leading risk. It does not remove the others.
The signs of a clogged dryer vent
Lists of warning signs online run long. The ones below are the ones a federal agency has put in writing.
- Loads take longer to dry. CPSC says that if clothing is still damp at the end of a typical cycle, or drying takes longer than normal, the lint screen or the exhaust duct may be blocked.
- Little or no air at the outside hood. CPSC says to check the outside vent while the dryer is running to make sure exhaust air is escaping. If it is not, the vent or the duct may be blocked.
- The flap on the hood stays shut. The Fire Administration tells owners to make sure the outdoor vent covering opens when the dryer is operating.
- A crushed or damaged duct behind the dryer. The Fire Administration says to check that the venting behind the dryer is not damaged, crushed or restricted.
- A nest. The Fire Administration’s report notes that nests of small birds or other animals can block a vent the way lint does.
Any one of these is a reason to have the vent cleaned, even if the last cleaning was recent.
One thing is not a sign to watch. If you see smoke or flames at the dryer, get out and call 911.
What you can check safely yourself
Three checks need no tools and no ladder.
The lint screen
The Fire Administration says to clean the lint filter before and after each cycle, and not to use the dryer without one. This is the one cleaning job that belongs to whoever does the laundry.
The outside hood
Find where the vent leaves the house. Start a load, walk outside and look at the hood from the ground:
- Is air coming out?
- Does the flap or cover open while the dryer runs?
- Is anything in the way, such as a nest, leaves or snow?
If the hood is high on a wall or on the roof, look from the ground. Do not climb to reach it.
Behind the dryer
Look at the short duct that joins the dryer to the wall. The Fire Administration’s two points are that it should not be damaged, crushed or restricted, and that lint builds up at the back of the dryer.
Note what the duct is made of. CPSC advises replacing plastic or foil accordion-type duct with rigid or corrugated semi-rigid metal duct. Its reason is that the flexible plastic or foil type traps lint more easily and is more susceptible to kinks or crushing, which can greatly reduce airflow.
If the dryer is gas, look without dragging it away from the wall. An NFPA tip sheet says a professional should inspect a gas dryer’s gas line and connection to make sure they are intact.
What is not on this list: taking the duct apart, opening the dryer cabinet, or anything on a roof. CPSC says the inside of the dryer chassis should be cleaned by a qualified service person.
When to have the whole run cleaned
Those checks cover the two ends. The run between them, from the back of the dryer to the hood outside, is the part you cannot see. That is where a yearly cleaning does its work.
The schedule the safety organizations give:
- The U.S. Fire Administration says to clean the dryer vent ductwork every year.
- An NFPA tip sheet says to clean lint out of the vent pipe once a year, or more often if you notice that drying takes longer than normal. It names a dryer lint removal service as the other way to get it done.
- The Chimney Safety Institute of America (CSIA) recommended in a 2002 press release that vents, dryer vents included, be inspected annually and cleaned as necessary by a certified technician.
Reasons to book sooner than a year:
- Any sign from the list above.
- A long run with bends. In a 2001 press release CSIA noted that dryers tend to be vented longer distances, with sharp turns and bends, and that this creates more places for lint to collect. New York’s residential code gives a sense of scale: its default limit for a dryer duct is 35 feet, and a 4-inch radius mitered 90-degree elbow counts as 5 feet of that, while smooth elbows with a larger radius count for less. The dryer maker’s installation instructions can set a different length. This is a design rule, not a verdict on the duct you have.
- Plastic or foil duct anywhere in the run.
- A nest or damage at the hood.
Our dryer vent cleaning clears lint from the dryer vent. The price is given on request. After you send a request, the team calls back as soon as possible to confirm the appointment, and that call is the time to ask. New customers get 15% off: tick the new customer box in the form, or say so when we call. We explain what we see and what it will cost before work starts.
Gas dryers and carbon monoxide
With a gas dryer the vent carries more than lint and damp air. New York’s fuel gas rules say a dryer’s exhaust must carry the moisture and any products of combustion to the outside of the building. The federal housing standard mentioned above lists carbon monoxide among the gases a dryer exhaust removes. A 2001 CSIA press release says that if a gas clothes dryer is improperly vented, deadly carbon monoxide can be forced back into a home.
That makes a blocked or disconnected vent on a gas dryer a carbon monoxide concern as well as a fire concern.
- If a carbon monoxide alarm sounds, get to fresh air and call 911.
- If you smell gas, leave the house and call the gas utility or 911.
Gas lines and gas connections are work for a professional. Do not try to repair one yourself.
Why winter matters in Buffalo and Rochester
Dryer fires have a season. The Fire Administration’s report found they were more frequent in fall and winter and peaked in January, with 11 percent of the year’s total.
Snow is the local addition. The National Weather Service’s 1991 to 2020 normals put yearly snowfall at 95.4 inches in Buffalo and 102.0 inches in Rochester. An NFPA tip sheet says to make sure the outdoor vent flap is not covered by snow, and NFPA’s carbon monoxide guidance says to check that the dryer vent is clear of snow build-up during and after a storm.
A look at the hood after each big snowfall takes a minute. It is the same look described above, from the ground.
If the house also has a fireplace, the same yearly rhythm applies to the chimney. Our guide on how often a chimney should be cleaned covers that, and every published price is on the price list.