Why a gas fireplace pilot light will not stay lit

When a gas fireplace pilot light will not stay lit, the gas valve is not getting the signal that proves a flame is there, so it shuts off the gas. Makers' manuals list a defective thermocouple or thermopile, a weak or dirty pilot flame, loose wiring, wind and an interrupted gas supply. After several tries, stop and call a technician.

Read the guideSee gas fireplace inspection

SafetyUpdated 7 min read

If you smell gas, stop here

Smell gas? Leave the house, then call your gas utility or 911. Do not try to relight the pilot first.

The local gas utility and the state say the same thing in their own words. National Fuel tells customers to leave the premises immediately and to make the call from a different location. The New York State Department of Public Service says to evacuate everyone immediately, to avoid anything that could create a spark, such as turning appliances or lights on or off or using a phone, and to call the gas utility or 911 once at a safe location. Regency’s lighting instructions add that an owner who smells gas should not try to light any appliance.

If a carbon monoxide alarm sounds, get to fresh air and call 911.

Everything below is for a fireplace with no gas smell. It explains causes. It is not a repair guide.

What the pilot light does

On a fireplace with a standing pilot, the pilot is a small flame that stays lit. A Travis Industries owner’s manual gives it two jobs: it ignites the main burners, and it plays a safety role.

The safety role depends on two small parts that sit in the pilot flame.

  • The thermocouple. Travis’s manual says it generates a small amount of electricity when the pilot flame heats it. If the pilot flame goes out, the thermocouple stops generating electricity and the gas valve automatically shuts off all gas.
  • The thermopile. In the same manual it supplies the power for the on/off switch, the remote control or the thermostat. Travis says that is why its fireplace can be operated when the power is out, although the blower will not run.

Travis describes the same logic from the valve’s side: the gas valve shuts off all gas if it does not receive a signal from the thermocouple.

So when a pilot will not stay lit, the valve is closing because it is not getting that small signal. Regency calls the shutoff a valuable safety feature. The real question is why the signal is missing.

Check which kind of pilot you have

Not every gas fireplace has a pilot that burns all the time.

  • Standing pilot. Travis says the pilot on its fireplace should be left on once lit, and that it stays lit unless the gas control valve is turned to OFF.
  • Intermittent pilot ignition. Heat & Glo’s owner manual for a current model says that in this system the pilot flame should turn off when the appliance is turned off, and that some optional control systems may allow it to remain lit. On many of these fireplaces, a pilot that is out while the fireplace is off is expected.

The manual for your model says which system you have. Heat & Glo says the model information is on the rating plate, which is usually in the control area of the fireplace.

The causes that makers’ manuals list

We read the troubleshooting sections of owner’s manuals from Regency, Travis Industries and Heat & Glo. None of them ranks causes by how often they happen, so this guide does not either. These are the groups they describe.

The thermocouple or thermopile

Regency’s troubleshooting guide for a standing pilot stove lists four possible causes of this kind: a defective thermopile, a defective thermocouple, loose thermopile leads, and a thermopile or thermocouple that is grounding out.

Regency’s guide has the technician test these parts with a millivolt meter, taking a reading at the gas valve.

A weak, dirty or misplaced pilot flame

The sensors work only if the flame reaches them. Regency describes a correct pilot as three strong blue flames: one around the thermopile, one around the thermocouple and one across the burner. It describes an incorrect one as small, probably yellow flames that do not make proper contact. Travis says the flame should touch the top of the thermocouple and about 3/8 inch of the top of the thermopile.

Regency’s guide has the technician clean and/or adjust the pilot so the flame is enveloped around both sensors. Heat & Glo’s yearly service list has a technician inspect the pilot flame’s pattern and strength and clean or replace the orifice as necessary.

Logs matter too. Regency’s P40 manual warns that broken logs can interfere with pilot operation.

Drafts and wind

Under frequent pilot outages, Regency’s guide lists a pilot flame that is too low or blowing high, which makes the pilot safety drop out.

Wind outside can be the source. An older Travis manual for a direct vent fireplace says the company’s experience is that intermittent high winds can adversely affect the flame and the pilot. Regency’s P40 manual says a poor draft or down drafting can result from high wind near big trees or adjoining roof lines.

A venting fault can shut the gas off as well. Regency’s manual for a stove that vents into a chimney describes a safety switch in the draft hood that detects a blocked chimney or a backdraft and shuts off the gas supply.

The gas supply

Travis’s manual says the pilot will go out if the gas is shut off, or if a propane tank runs out or runs low. Its troubleshooting table gives a gas supply that has been shut off as the possible cause when a pilot goes out once a month or more.

Heat & Glo’s manual lists another supply-side reason an intermittent pilot fireplace may fail to start: an accumulation of air in the gas line after an extended period of inactivity.

The gas valve

Regency lists a defective automatic gas valve among the possible causes. Travis notes that the valve shuts off all gas if any component is damaged or the wiring is damaged.

Why the fix is a job for a technician

The manuals are plain about who does this work.

  • Regency marks its troubleshooting guide “for service technicians only”.
  • Heat & Glo says its troubleshooting guide can only be used by a qualified service technician.
  • Regency says thermopile and thermocouple replacement should be performed by an authorized, factory-trained dealer, and that homeowners should not do maintenance on gas components.

What the manuals leave to the owner is small.

  • Follow the lighting instructions for your own model, exactly as printed on the fireplace and in its manual. They differ from model to model, which is why none are repeated here.
  • Know when to stop. Regency’s lighting instructions say that if the pilot will not stay lit after several tries, turn the gas control knob to OFF and call a service technician or the gas supplier. They also say to stop and call immediately if the control knob does not pop back up when released.
  • Look, and leave the adjusting alone. Travis’s owner table lists two checks before a service call for a pilot that will not light: that the gas shut-off valves are on and, with propane, the tank level. If you are not sure which valve is which, leave it and say so when you call. From the ground, look at the vent cap outside: Heat & Glo’s manual has the homeowner inspect the termination cap seasonally for blockage such as bird nests, leaves and snow. Do not climb to reach it.

Do not try to keep a pilot burning by getting around the valve. The shutoff is the safety system.

What to tell the technician

Have these ready when you call or book:

  • Make, model and serial number. They are on the rating plate, which Heat & Glo says is usually in the control area of the fireplace.
  • Fuel. Natural gas or propane.
  • Ignition. A pilot that burns all the time, or one that lights only when you turn the fireplace on.
  • Exactly what happens. Does the pilot go out the moment you release the knob? Does it hold for hours or days and then drop out? Does the pilot stay on while the main burner will not light?
  • When it happens. On windy days, after snow, at the first fire after summer, or with no pattern. Add when the fireplace was last serviced.
  • What the pilot flame looks like. Strong and blue, or small and yellow.
  • What changed. Logs moved or broken, the glass taken off for cleaning, the gas shut off for other work, or work on the roof or siding near the vent.
  • Anything else you noticed, such as soot on the glass or an unusual odor. The Hearth, Patio & Barbecue Association says unusual odors or flames are often a sign the fireplace is not operating properly.

How a ChimneY Royal inspection fits

Our gas fireplace inspection is a check of the burner, logs, pilot, controls and venting. The price is given on request. Send a request, call or message us on WhatsApp, and say that the pilot will not stay lit. After a request, the team calls back as soon as possible to confirm the appointment, and that call is the time to ask the price. New customers get 15% off: tick the new customer box in the form, or say so when we call.

We explain what we see and what it will cost before work starts. Our published prices are on the price list.

Snow and cold starts in Buffalo and Rochester

Two things have a winter side here.

  • Snow. The National Weather Service’s 1991 to 2020 normals put yearly snowfall at 95.4 inches in Buffalo and 102.0 inches in Rochester, and snow is one of the vent cap blockages Heat & Glo names. The National Fire Protection Association says to make sure the fireplace vent is clear of snow build-up during and after a storm.
  • Cold starts. Regency says its electronic ignition models may need a few tries to start on cold or damp days, and that this is normal and not a defect.

Key takeaways

The short version of this guide.

  • If you smell gas, leave the house, then call your gas utility or 911. Do not try to relight the pilot first.

  • A thermocouple heated by the pilot flame keeps the gas valve open. When it stops sensing a flame the valve shuts off the gas, so a pilot that drops out is a safety shutoff.

  • Makers' manuals list a defective or loose thermocouple or thermopile, a weak or dirty pilot flame, wind and drafts, an interrupted gas supply and a faulty gas valve.

  • Regency's lighting instructions say to stop after several tries, turn the gas control knob to OFF and call a service technician or the gas supplier.

  • Tell the technician the make and model, the fuel, the kind of ignition, and exactly when and how the pilot goes out.

Questions

Asked about this topic, answered directly.

Why does my gas fireplace pilot light keep going out?

Because the gas valve is not getting the small electrical signal that proves the pilot flame is there. Manuals from Regency and Travis Industries list possible causes: a defective or loose thermocouple or thermopile, a pilot flame that is too low or blowing, wiring that is grounding out, a gas supply that was shut off, and a defective gas valve.

Is it the thermocouple?

It may be. Regency's troubleshooting guide lists a defective thermocouple and a defective thermopile among the possible causes, along with loose leads, grounding and a defective gas valve. None of the manuals we read ranks them. A technician tells them apart with a meter reading at the gas valve, and Regency says replacement should be done by an authorized dealer.

Can I relight the pilot light myself?

Only by following the lighting instructions printed on your own fireplace and in its manual, and only if there is no gas smell. Regency's instructions say that if the pilot will not stay lit after several tries, turn the gas control knob to OFF and call a service technician or the gas supplier. If you smell gas, leave the house and call the gas utility or 911.

Can wind blow out a gas fireplace pilot light?

Manufacturers say wind can affect it. An older Travis Industries manual says intermittent high winds can adversely affect the flame and pilot of its direct vent fireplace. A Regency manual says high wind near big trees or adjoining roof lines can cause a poor draft or down drafting. If the pilot goes out on windy days, tell the technician.

Should a gas fireplace pilot light always be on?

It depends on the ignition system. Travis Industries says the standing pilot on its fireplace should be left on once lit, and Regency's instructions say the pilot may be shut off during long periods of non-use to conserve fuel. Heat & Glo says that in an intermittent pilot ignition system the pilot flame should turn off when the appliance is turned off, although some optional control systems may let it stay lit.

How much does it cost to have a pilot light problem looked at?

ChimneY Royal's gas fireplace inspection is priced on request. It is a check of the burner, logs, pilot, controls and venting. To get the price, send a request, call or message us on WhatsApp, and say that the pilot will not stay lit. New customers get 15% off: tick the new customer box in the form, or say so when we call.

We explain what we see and what it will cost before work starts.

The service behind this guide

15% off for new customers. Mention it when you book.

Sources

12 sources
  1. The pilot ignites the main burners and plays a safety role. The thermocouple and thermopile generate electricity when heated by the pilot flame, and if the pilot goes out the gas valve shuts off all gas. The pilot will go out if the gas is shut off or a propane tank runs out or low. The pilot flame should touch the thermocouple and about 3/8 inch of the thermopile. The owner table lists gas shut-off valves and tank level as checks.

    Travis Industries, DVL direct vent fireplace owner's manual (document 93508110)travisindustries.com

  2. The troubleshooting guide, marked for service technicians only, lists a defective thermopile or thermocouple, loose leads, grounding out and a defective gas valve for a pilot that will not stay lit, and a pilot flame that is too low or blowing high for frequent pilot outages. Correct and incorrect pilot flame patterns. A switch in the draft hood shuts off the gas when it detects a blocked chimney or a backdraft.

    Regency F33 freestanding gas stove, owners and installation manual (March 21, 2019)manuals.regency-fire.com

  3. If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call a service technician or the gas supplier. Stop and call if the knob does not pop up when released. If you smell gas, do not try to light any appliance. Broken logs can interfere with pilot operation. High wind near big trees or adjoining roof lines can cause poor draft or down drafting. The pilot may be shut off during prolonged non-use.

    Regency P40 direct vent gas fireplace, owners and installation manualassets.regency-fire.com

  4. If the pilot flame goes out, the valve shuts down and the fireplace turns off, which Regency calls a safety feature. Electronic ignition may need a few tries on cold or damp days. Thermopile and thermocouple replacement should be performed by an authorized, factory-trained dealer.

    Regency Fireplace Products, fireplace care FAQregency-fire.com

  5. Homeowners should not do maintenance on gas components.

    Regency Fireplace Products, gas fireplace maintenance guideregency-fire.com

  6. In an intermittent pilot ignition system the pilot flame should turn off when the appliance is turned off, and some optional control systems may allow it to remain lit. Yearly technician tasks include inspecting the pilot flame pattern and strength and cleaning or replacing the orifice spud as necessary. Accumulation of air in the gas line after an extended period of inactivity is listed as a reason an appliance may not start. The troubleshooting guide can only be used by a qualified service technician. Model information is on the rating plate, usually in the control area. The homeowner is to inspect the termination cap seasonally for blockage such as bird nests, leaves and snow.

    Heat & Glo owner manual (6000 and 8000 series gas fireplaces)downloads.hearthnhome.com

  7. In the vertical termination requirements, the maker notes that its experience is that intermittent high winds can adversely affect the flame and pilot of this appliance, and requires a high-wind vertical termination.

    Travis Industries, 36DV direct vent fireplace owner's manual (November 1995)travisindustries.com

  8. If you smell gas, leave the premises immediately and contact National Fuel or call 911 from a different location.

    National Fuel, gas safetynationalfuel.com

  9. If you suspect a gas leak, evacuate everyone from your home immediately and move away from the premises. Do not use or do anything that could create a spark, such as turning appliances or lights on or off or using a telephone. Once at a safe location, contact the local gas utility or dial 911.

    New York State Department of Public Service, Electric and Natural Gas Safety Tips (consumer guide, December 2023)dps.ny.gov

  10. Unusual odors or flames are often a sign the fireplace is not operating properly.

    Hearth, Patio & Barbecue Association, gas-burning maintenance tipsmembers.hpba.org

  11. Normal annual snowfall is 95.4 inches in Buffalo and 102.0 inches in Rochester.

    National Weather Service Buffalo, 1991 to 2020 climate normalsweather.gov

  12. During and after a snowstorm, make sure vents for the dryer, furnace, stove and fireplace are clear of snow build-up.

    NFPA, carbon monoxide safetynfpa.org

Ready for winter, crown to hearth.

A check of the burner, logs, pilot, controls and venting of your gas fireplace. Price on request.

Book a visit

After a request, the team calls back as soon as possible to confirm the appointment.

A phone number or an email. One is enough.

What you have noticed, and the days or times that suit you. For a home sale, a new appliance or after a fire, say so here so the scope can be confirmed.

We use your details only to answer this request. See the privacy page.

Ask ChimneY Royal

Ask ChimneY Royal

Assistant:

I am ChimneY Royal's automated assistant. I answer from our price list and guides. For an emergency call 911.

Suggested questions

Please do not type your name, phone or address here. The booking form is the place for them.