If you smell gas, stop here
Smell gas? Leave the house, then call your gas utility or 911. Do not try to relight the pilot first.
The local gas utility and the state say the same thing in their own words. National Fuel tells customers to leave the premises immediately and to make the call from a different location. The New York State Department of Public Service says to evacuate everyone immediately, to avoid anything that could create a spark, such as turning appliances or lights on or off or using a phone, and to call the gas utility or 911 once at a safe location. Regency’s lighting instructions add that an owner who smells gas should not try to light any appliance.
If a carbon monoxide alarm sounds, get to fresh air and call 911.
Everything below is for a fireplace with no gas smell. It explains causes. It is not a repair guide.
What the pilot light does
On a fireplace with a standing pilot, the pilot is a small flame that stays lit. A Travis Industries owner’s manual gives it two jobs: it ignites the main burners, and it plays a safety role.
The safety role depends on two small parts that sit in the pilot flame.
- The thermocouple. Travis’s manual says it generates a small amount of electricity when the pilot flame heats it. If the pilot flame goes out, the thermocouple stops generating electricity and the gas valve automatically shuts off all gas.
- The thermopile. In the same manual it supplies the power for the on/off switch, the remote control or the thermostat. Travis says that is why its fireplace can be operated when the power is out, although the blower will not run.
Travis describes the same logic from the valve’s side: the gas valve shuts off all gas if it does not receive a signal from the thermocouple.
So when a pilot will not stay lit, the valve is closing because it is not getting that small signal. Regency calls the shutoff a valuable safety feature. The real question is why the signal is missing.
Check which kind of pilot you have
Not every gas fireplace has a pilot that burns all the time.
- Standing pilot. Travis says the pilot on its fireplace should be left on once lit, and that it stays lit unless the gas control valve is turned to OFF.
- Intermittent pilot ignition. Heat & Glo’s owner manual for a current model says that in this system the pilot flame should turn off when the appliance is turned off, and that some optional control systems may allow it to remain lit. On many of these fireplaces, a pilot that is out while the fireplace is off is expected.
The manual for your model says which system you have. Heat & Glo says the model information is on the rating plate, which is usually in the control area of the fireplace.
The causes that makers’ manuals list
We read the troubleshooting sections of owner’s manuals from Regency, Travis Industries and Heat & Glo. None of them ranks causes by how often they happen, so this guide does not either. These are the groups they describe.
The thermocouple or thermopile
Regency’s troubleshooting guide for a standing pilot stove lists four possible causes of this kind: a defective thermopile, a defective thermocouple, loose thermopile leads, and a thermopile or thermocouple that is grounding out.
Regency’s guide has the technician test these parts with a millivolt meter, taking a reading at the gas valve.
A weak, dirty or misplaced pilot flame
The sensors work only if the flame reaches them. Regency describes a correct pilot as three strong blue flames: one around the thermopile, one around the thermocouple and one across the burner. It describes an incorrect one as small, probably yellow flames that do not make proper contact. Travis says the flame should touch the top of the thermocouple and about 3/8 inch of the top of the thermopile.
Regency’s guide has the technician clean and/or adjust the pilot so the flame is enveloped around both sensors. Heat & Glo’s yearly service list has a technician inspect the pilot flame’s pattern and strength and clean or replace the orifice as necessary.
Logs matter too. Regency’s P40 manual warns that broken logs can interfere with pilot operation.
Drafts and wind
Under frequent pilot outages, Regency’s guide lists a pilot flame that is too low or blowing high, which makes the pilot safety drop out.
Wind outside can be the source. An older Travis manual for a direct vent fireplace says the company’s experience is that intermittent high winds can adversely affect the flame and the pilot. Regency’s P40 manual says a poor draft or down drafting can result from high wind near big trees or adjoining roof lines.
A venting fault can shut the gas off as well. Regency’s manual for a stove that vents into a chimney describes a safety switch in the draft hood that detects a blocked chimney or a backdraft and shuts off the gas supply.
The gas supply
Travis’s manual says the pilot will go out if the gas is shut off, or if a propane tank runs out or runs low. Its troubleshooting table gives a gas supply that has been shut off as the possible cause when a pilot goes out once a month or more.
Heat & Glo’s manual lists another supply-side reason an intermittent pilot fireplace may fail to start: an accumulation of air in the gas line after an extended period of inactivity.
The gas valve
Regency lists a defective automatic gas valve among the possible causes. Travis notes that the valve shuts off all gas if any component is damaged or the wiring is damaged.
Why the fix is a job for a technician
The manuals are plain about who does this work.
- Regency marks its troubleshooting guide “for service technicians only”.
- Heat & Glo says its troubleshooting guide can only be used by a qualified service technician.
- Regency says thermopile and thermocouple replacement should be performed by an authorized, factory-trained dealer, and that homeowners should not do maintenance on gas components.
What the manuals leave to the owner is small.
- Follow the lighting instructions for your own model, exactly as printed on the fireplace and in its manual. They differ from model to model, which is why none are repeated here.
- Know when to stop. Regency’s lighting instructions say that if the pilot will not stay lit after several tries, turn the gas control knob to OFF and call a service technician or the gas supplier. They also say to stop and call immediately if the control knob does not pop back up when released.
- Look, and leave the adjusting alone. Travis’s owner table lists two checks before a service call for a pilot that will not light: that the gas shut-off valves are on and, with propane, the tank level. If you are not sure which valve is which, leave it and say so when you call. From the ground, look at the vent cap outside: Heat & Glo’s manual has the homeowner inspect the termination cap seasonally for blockage such as bird nests, leaves and snow. Do not climb to reach it.
Do not try to keep a pilot burning by getting around the valve. The shutoff is the safety system.
What to tell the technician
Have these ready when you call or book:
- Make, model and serial number. They are on the rating plate, which Heat & Glo says is usually in the control area of the fireplace.
- Fuel. Natural gas or propane.
- Ignition. A pilot that burns all the time, or one that lights only when you turn the fireplace on.
- Exactly what happens. Does the pilot go out the moment you release the knob? Does it hold for hours or days and then drop out? Does the pilot stay on while the main burner will not light?
- When it happens. On windy days, after snow, at the first fire after summer, or with no pattern. Add when the fireplace was last serviced.
- What the pilot flame looks like. Strong and blue, or small and yellow.
- What changed. Logs moved or broken, the glass taken off for cleaning, the gas shut off for other work, or work on the roof or siding near the vent.
- Anything else you noticed, such as soot on the glass or an unusual odor. The Hearth, Patio & Barbecue Association says unusual odors or flames are often a sign the fireplace is not operating properly.
How a ChimneY Royal inspection fits
Our gas fireplace inspection is a check of the burner, logs, pilot, controls and venting. The price is given on request. Send a request, call or message us on WhatsApp, and say that the pilot will not stay lit. After a request, the team calls back as soon as possible to confirm the appointment, and that call is the time to ask the price. New customers get 15% off: tick the new customer box in the form, or say so when we call.
We explain what we see and what it will cost before work starts. Our published prices are on the price list.
Snow and cold starts in Buffalo and Rochester
Two things have a winter side here.
- Snow. The National Weather Service’s 1991 to 2020 normals put yearly snowfall at 95.4 inches in Buffalo and 102.0 inches in Rochester, and snow is one of the vent cap blockages Heat & Glo names. The National Fire Protection Association says to make sure the fireplace vent is clear of snow build-up during and after a storm.
- Cold starts. Regency says its electronic ignition models may need a few tries to start on cold or damp days, and that this is normal and not a defect.